The building or project condition
An older school building in West Perth, with an existing masonry opening that needed a fire-rated door and frame.
What FRS delivered
- Supply and installation of one plywood-faced fire-rated door and fire-rated frame, rated -/120/30
- A frame fitted into an 890 mm by 2050 mm masonry opening, with a 750 mm by 1980 mm door leaf
- Certificate of compliance and a door register entry for the doorset
What made it difficult
- Old masonry: an arched brick and stone opening, not a new stud wall
- An opening that did not match a standard door size, so the frame had to take up the difference
- The frame had to be fixed and sealed to the masonry in a way the tested doorset allows
What was recorded at close-out
- Certificate of compliance for the fire door and frame
- Door register entry
A fire door is only as good as the opening it sits in. In a new building the opening is built for the door. In an old one the door has to be made to work in the opening that is there, and the gap between the frame and the masonry is part of the fire separation.
One door is a small job. Getting it right in old fabric is not.